Bologna, 1 January ManagingDirectorA. FAAC strongly recommends to follow these instructions literally for the safety of persons. Improperinstallation or misuse of the product will cause very serious damages to persons. Countries outside the EC shall follow the regulations above besides their national normative references in order to offerthe utmost safety.

Alternatively, use a 6A thermomagnetic breaker with multi-pole switching. In any case, further safety devicesshall be installed. The automation could be operatedunintentionally. These operations must be carriedout exclusively by qualified personnel. By using FAAC TOTUM it ispossible to modify an extremely wide range of parameters tocustomise card operation according to the requirements andcharacteristics of the automation.

FAAC TOTUM also has a diagnostic function signalling on thedisplay the state of the gate and inputs in real time and thevoltage levels on the card and verifies operation of theautomation and the cycle counts performed. High-tension terminal block J3 is used to power the motorsand the flashing light. High-tension terminal block J4 is used for line voltage input.

Fuse F2 5x20 1. This means any device pushbutton, detector,etc. This means any device e. To install more than one stop device connectthe N.

If the closing safety devices are activated when the gateis open, they prevent the leaves from closing. During closure, activation of the safety devicescauses the gate leaves to reverse their directionof movement.

They are not activated duringopening. The function of the closure safety devices isto safeguard the area affected by themovement of the leaves during closure B,fig. During opening the safety devices stop themovement of the gate leaves. When releasedthey reverse the direction of movement. The function of the opening safety devicesis to safeguard the area behind the gateleaves A, fig. ABBAAIt is possible to connect devices which operate simultaneouslyas opening and closing safety devices see example of safetydevice connection.

The gate leaves stop if these safety devices are activated duringopening, then carry on opening when they are released.

The leaves stop moving if these safety devices are activatedduring closure, then change direction and open when they arereleased. The warning light 24 Vdc 3 W max.

Do not exceed the stated power. Connect by inserting the connector on the accessories cardsperpendicularly to the corresponding connector J5 on theP. Turn off the power supply at the electronic control unit beforeconnecting and disconnecting. To calculate absorbedpower, refer to table 6. Use a dedicated decoder for each accessory type.

The connector can be fitted one way only so that the moduleterminal block is oriented in the same direction as the P cardterminal block.

Disconnect power from the card before insertingor removing the modules. The cable holes and tube grips used for wiring must not reducethe housing protection of the enclosure. The P is provided with standard preset programming thecharacteristics are given in Table 2.

For details of operation,refer to Table 9. If the first opening pulse closes one or both leaves, invert theelectric motor phases brown and black cables on the cardterminal block for each leaf that closes. Each module has two connectors: one on the soldered side, theother on the component side.

The connector on the soldered side allows the module to beinserted into card P connector J1 or into the connector onthe component side of another module. The currently available modules are:MEL-1 : single electric lock management module. MEL-2 : double electric lock management module. MEI : input expansion module.

The electric lock management modules must not both beinstalled on the same P card. A freecontact is available betweenterminals 3 COM and 4 N. In the connection diagram shownin Fig. A different type of electric lock ora number of electric locks inparallel can be installed using anadequate external power supplyas shown in the diagram in Fig. In this case do not exceed themaximum permitted contactcapacity 5A max. With the FAAC TOTUM it is possible to program this contact toclose as follows:- only when the gate starts to open- only when the gate starts to close- when the gate starts to open and when it starts to close.

Twofree contacts are availablebetween terminals 3 COM , 5 N. Following the connectiondiagram shown in Fig. It is possible to install differenttypes of electric locks or a numberof electric locks in parallel usingexternal power sources followingthe connection diagram shownin Fig. In this case do not exceed theFig. Single-leaf automationIn single-leaf automation the closure electric lock Fig. Double-leaf automationIn double-leaf automation the electric lock Fig. Closing the contacts between terminals and activatesthe electric lock s connected to them.

By using the FAAC TOTUM these contacts can be programmedto close as follows:- only when the gate starts to open- only when the gate starts to close- when the gate starts to open and when it starts to close.

It must be inserted in the Pcard connector J1. It must not beinstalled on top of any electriclock management modulesalready present in the connectorJ1. On the MEI module there are 6additional inputs with respect tothe standard 5 of the Pelectronic card described above. This input is specifically for connectingpneumatic safety edges which interveneduring the closure phase.

Opening this contact during the closure phasecauses timed inversion 2 sec. This input is specifically for connectingpneumatic safety edges which interveneduring the opening phase.

Opening this contact during the opening phasecauses timed inversion 2 sec. It is possible to connect devices which activatesimultaneously, such as opening and closing safetyedges see connection examples in section 8. If these safety devices activate during opening orclosing, they stop the gate. For details of operation, refer to Table 9. Once the panic opening command has beengiven, normal operation can be resumed onlyby resetting the contact and turning theelectronic control unit off and then back onagain.

Input for Leaf 1 opening limit switch contact. The limit switch is a device with an N. Gatecoder and Limit switch not usedIn this case the input is not active. Input for Leaf 1 closure limit switch contact. Two-leaf gates require a Gatecoder for each leaf. Furthermore the Gatecoder also constitutes an effectiveelectronic anti-crushing safety device which can be disabled because if an obstacle is detected while the leaf is moving itreverses the direction of movement.

The obstacle detection time before reversal of movement isprogrammable standard 1 sec. The tongue 2 must be facing the post. Lock by tightening the nut. At the same time insert the tongue 2 on the fork 1 into theGatecoder housing. Simply insert the MEI module into theP with the standard configuration.

If neither the Gatecoder orthe limit switches are used they are inactive. The check is always performed before the motors are started. It turns off the power supply temporarily to the photocell transmitterand checks that this causes the contact on the receiver to open.

If it does not, movement of the leaves is inhibited for safety reasons. Tempo delay ritardo time AP. Tempo delay ritardo time CH. Short-link Link Embed. Share from cover. Share from page:. More magazines by this user. Close Flag as Inappropriate. You have already flagged this document. Thank you, for helping us keep this platform clean. The editors will have a look at it as soon as possible.

Delete template? Cancel Delete. Cancel Overwrite Save. Don't wait! Try Yumpu. Start using Yumpu now!

BROTHER SKANNAUS PDF

FAAC 460-P Manuals

Bologna, 1 January ManagingDirectorA. FAAC strongly recommends to follow these instructions literally for the safety of persons. Improperinstallation or misuse of the product will cause very serious damages to persons. Countries outside the EC shall follow the regulations above besides their national normative references in order to offerthe utmost safety. Alternatively, use a 6A thermomagnetic breaker with multi-pole switching. In any case, further safety devicesshall be installed. The automation could be operatedunintentionally.

LAS ARMONIAS DE COLOR AUGUSTO GARAU PDF

FAAC 460 P Control Panel Manual

.

BICALUTAMIDA BULA PDF

France Automatismes vous conseille

.

Related Articles